Eaton 8 Zone control panel for conventional fire systems
Conventional Fire Alarm Panels

Eaton 8 Zone control panel for conventional fire systems

Eaton·SKU: EATON-F-5D8EBD1374E2

Eaton’s 8 zone conventional fire alarm system panel is designed to be straightforward and easy to use. Created for small to medium-sized applications including schools, warehouses, retail stores and office buildings, it features an intuitive interface makes programming and maintenance hassle-free. A

Request a quote

Description

Eaton’s 8 zone conventional fire alarm system panel is designed to be straightforward and easy to use. Created for small to medium-sized applications including schools, warehouses, retail stores and office buildings, it features an intuitive interface makes programming and maintenance hassle-free. Approved to EN54-2&4, it has a modern, robust and discreet enclosure that blends effortlessly into contemporary surroundings. World leaders in fire alarm and detection systems, Eaton has a range of conventional devices to create a system to suit your application such as bells for signalling change in schools or warehouses.

Highlights

  • Testing: One man test facility
  • Interlink relay: Function for connecting 2 panels
  • Isolator barrier: Zones are switchable

Switch between normal and intrinsically safe modes for peace of mind in industrial applications

The 8 zone panel offers a standard mode and an intrinsically safe mode. In the standard mode, the maximum loading is 32 detectors and manual call points per zone, in the intrinsically safe mode the maximum loading switches to 10 detectors and manual call points per zone. With the addition of an isolator barrier, the panel has the flexibility to monitor standard or intrinsically safe conventional zone circuits, making it suitable for industrial applications.

Intelligent design for an intelligent panel

The aesthetically pleasing control panel has a modern and discreet enclosure to ensure the device does not look out of place in public areas. The device accommodates simple system testing by a single fire alarm technician and its interlink relay gives greater flexibility to configure zones to work in ATEX areas using an isolator barrier.

Instant recognition, for fire and non-fire applications

Designed for not just fire applications, with the addition of a conventional bell the 8 zone control panel can also be used to sound class change in schools or to signal shift changeover in factories.

BiWire Flexi - Your simpler, cheaper, more versatile choice for new & old fire projects

Whether fitting out a building extension, retrofitting an outdated system or looking to benefit from the cost and time benefits of two-wire technology on a new build and want to utilise certain conventional devices; BiWire Flexi gives you the power to adapt the system to the site.

Product codes

  • 8 Zone Conventional Panel | EFCV8
  • End of Line Module | EOLM-1
  • 8 Zone Relays + FRE/FPE | BWOB8Z

Additional technical details

  • Repeater Port (use of this port is outside the scope of EN54): Type - RS485 Nodes - 1

Product family: specifications and ordering options vary by model. Refer to the model details and official documentation.

Official Eaton product page

Technical Specifications

Alarm Zone Voltage (Vmin - Vmax)31Vdc - 33Vdc
Auxilliary OutputV - 18.15-30.7V Imax - 50mA Fuse - 50mA PTC
Dimensions (WxHxD)375mm x 366mm x 134mm
End of Line A TerminationStandard Conventional Zones - EOLM-1 Only Intrinisically Safe Zones - SKI Resistor
End of Line B Termination6K8 Resistor
Fuse Protection per Circuit250mA PTC
Fuse Protection Per Zone250mA PTC
Input Voltage Range18.75 - 30.7V
IP RatingIP30
Manufacturer highlight: Interlink relayFunction for connecting 2 panels
Manufacturer highlight: Isolator barrierZones are switchable
Manufacturer highlight: TestingOne man test facility
MaterialsPC ABS Front and Rear
Maximum Current Drawn from Battery2.7A
Maximum Loading per Circuit250mA
Maximum Loading per ZoneStandard Mode: 32 detectors and manual call points Intrisically Safe Mode: 10 detectors and manual call points
Number of Sounder Circuits230V Ah +10%/-15% 50Hz
Number of Zones8
Operating Temperature-5°C to +40°C
Relative Humidity (Non-condensing)93% +/-3%
StandardsEN54 Part 2 CIE & Part 4 PSE, BS5839 Part 1
Standby Zone Voltage (Vmin - Vmax)19Vdc - 23Vdc
Unmonitored Inputs: Class ChangeOpen Circuit - Normal Panel Operation Short Circuit - Activate All Sounders
Unmonitored Outputs - Fire, Fault, Interlink RelayType - Volt-Free, Single Pole Double Throw Rating - 30Vdc, 1A Fuse - 500mA PTC
Weight (excluding batteries)2.25Kg

Documents & Technical Downloads

Simplex 4007-9202 (4007ES FACP, IDNAC)

Simplex 4007-9202 (4007ES FACP, IDNAC)

Indicative Price

from

Simplex 4004-9302 (Suppression Releasing Panel)

Simplex 4004-9302 (Suppression Releasing Panel)

Indicative Price

from

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)

Indicative Price

from

Simplex 4007-9102 (Fire Alarm Control Panel)

Simplex 4007-9102 (Fire Alarm Control Panel)

Indicative Price

from