The DualGuard-S central battery system supplies safety and escape sign luminaires with reliable power (230 V AC/220 V DC), automatically checks itself and monitors each of the connected CG-S luminaires (up to 20 per circuit) directly via the supply cable. Thanks to the STAR technology, the switching

Request a quote

Description

The DualGuard-S central battery system supplies safety and escape sign luminaires with reliable power (230 V AC/220 V DC), automatically checks itself and monitors each of the connected CG-S luminaires (up to 20 per circuit) directly via the supply cable. Thanks to the STAR technology, the switching mode of each connected CG-S luminaire in a 50 Hz or 60 Hz network can be programmed as required via the central battery system controller. This means that mixed operation of the continuous light, switched continuous light and standby light modes is possible in one and the same circuit - without any additional data cable. The central battery system can be monitored and controlled via the ACU DG module and the 4.3" or 7" display with non-volatile program memory. The system automatically checks the functioning of all connected devices and emergency luminaires and will issue an alert in the event of a fault.

Eaton emergency lighting systems, over 50 years of safe evacuation expertise

Our reliable and high quality products are known and specified worldwide. The passion and expertise of our employees ensures comprehensive, future-oriented solutions and high customer satisfaction.

Order details

  • Order no. | Type | Included with delivery
  • 40071362511 | DualGuard-S 28 | Free-standing cabinet with optimized wiring system for central battery system CEAG DualGuard-S 28, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 88 final circuits, or a maximum of 28 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
  • 40071362510 | DualGuard-S 20 | Free-standing cabinet with optimized wiring system for central battery system CEAG DualGuard-S 20, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 88 final circuits, or a maximum of 20 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
  • 40071362540 | DualGuard-S LAD 100 | Free-standing cabinet for central battery system CEAG DualGuard-S LAD 100A, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 16 final circuits, or a maximum of 4 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
  • 40071362520 | DualGuard-S 12C | Compact cabinet for central battery system CEAG DualGuard-S 12C, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 48 final circuits, or a maximum of 12 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
  • 40071362523 | DualGuard-S 12C6 | Compact cabinet for central battery system CEAG DualGuard-S 12C6, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 48 final circuits, or a maximum of 12 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
  • 40071362524 | DualGuard-S 20C6 | Compact cabinet for central battery system CEAG DualGuard-S 20C6, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 68 final circuits, or a maximum of 20 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
  • 40071362521 | DualGuard-S 12C4 | Compact cabinet for central battery system CEAG DualGuard-S 12C4, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 48 final circuits, or a maximum of 12 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
  • 40071362525 | DualGuard-S 4C3 | Compact cabinet for central battery system CEAG DualGuard-S 4C3, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 20 final circuits, or a maximum of 5 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
  • 40071362513 | DualGuard-S US 38 | Free-standing cabinet for substations CEAG DualGuard-S US-S 38, equipped with advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 88 final circuits, or a maximum of 38 variable circuit boards. Please note! The TFT touch display is not part of the cabinet module.
  • 40071362512 | DualGuard-S US 30 | Free-standing cabinet for substations CEAG DualGuard-S US-S 30, equipped with advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 88 final circuits, or a maximum of 30 variable circuit boards. Please note! The TFT touch display is not part of the cabinet module.
  • 40071362532 | DualGuard-S US 23 | Wall cabinet for CEAG DualGuard-S US-S 23 substations, equipped with advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 52 final circuits, or a maximum of 23 variable circuit boards. Please note! The TFT touch display is not part of the cabinet module.
  • 40071362531 | DualGuard-S US 15 | Wall cabinet for CEAG DualGuard-S US-S 15 substations, equipped with advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 32 final circuits, or a maximum of 15 variable circuit boards. Please note! The TFT touch display is not part of the cabinet module.
  • 40071362530 | DualGuard-S US 7 | Wall cabinet for CEAG DualGuard-S/US-S 7 substations, equipped with advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 28 final circuits, or a maximum of 7 variable circuit boards. Please note! The TFT touch display is not part of the cabinet module.
  • 40071362519 | DualGuard-S US SOU2 | Small distribution board for DualGuard-S/US-S SOU2 substations, equipped with two SOU CG-S 2x4A circuit modules
  • 40071362518 | DualGuard-S US SOU1 | Small distribution board for DualGuard-S/US-S SOU1 substations, equipped with one SOU CG-S 2x4A circuit module
  • 40071362516 | DualGuard-S ESF30 15-P | Wall cabinet for substations with 30 minutes of functional integrity during fire from outside CEAG DualGuard-S ESF30 15-P, equipped with 4.3" TFT touch display, advanced control unit (ACU DG-S) and power supply unit (PSU). With extra space for adding a maximum of 40 final circuits, or a maximum of 15 variable circuit boards.
  • 40071362517 | DualGuard-S ESF30 30P | Free-standing cabinet for substations with 30 minutes of functional integrity during fire from outside CEAG DualGuard-S ESF30 30-P, equipped with 4.3" TFT touch display, advanced control unit (ACU DG-S) and power supply unit (PSU). With extra space for adding a maximum of 58 final circuits, or a maximum of 30 variable circuit boards.
  • 40071362538 | DualGuard-S ESF30 SOU5 | Wall cabinet for substations with 30 minutes of functional integrity during fire from the outside DualGuard-S ESF30 SOU5, equipped with five SOU CG-S 2x4A circuit modules
  • 40071362537 | DualGuard-S ESF30 SOU3 | Wall cabinet for substations with 30 minutes of functional integrity during fire from outside DualGuard-S ESF30 SOU3, equipped with three SOU CG-S 2x4A circuit modules
  • 40071362536 | DualGuard-S ESF30 SOU2 | Wall cabinet for substations with 30 minutes of functional integrity during fire from the outside DualGuard-S ESF30 SOU2, equipped with two SOU CG-S 2x4A circuit modules
  • 40071362535 | DualGuard-S ESF30 SOU1 | Wall cabinet for substations with 30 minutes of functional integrity during fire from the outside DualGuard-S ESF30 SOU1, equipped with one SOU CG-S 2x4A circuit module

Product family: specifications and ordering options vary by model. Refer to the model details and official documentation.

Official Eaton product page

Documents & Technical Downloads

DualGuard-S - EULA Firmware EN

Application notes · en

DualGuard-S - Brochure

Brochures · en

Emergency Lighting (Central Battery Systems) - Global Catalogue

Catalogues · en

3-PM / 3-PM-IO / 3-PM-IO-INV - Attestation of Conformity

Certification reports

8PM-I-Bus module / 3PM-S - EU Declaration of Conformity

Certification reports

BBM - EU Declaration of Conformity

Certification reports · en

BCM.1 - EU Declaration of Conformity

Certification reports

CM 3.4A - EU Declaration of Conformity

Certification reports

DualGuard-S (CEAG) - UAE

Certification reports · en

DualGuard-S - Attestation of Conformity

Certification reports · en

DualGuard-S - Declaration of Conformity

Certification reports · en

DualGuard-S - ENEC

Certification reports · en

DualGuard-S - ESF30 EU Declaration of Conformity

Certification reports

DualGuard-S - KEMA-KEUR

Certification reports · en

DualGuard-S with BBM - EU Declaration of Conformity

Certification reports · en

HMI + ACU DG-S - EU Declaration of Conformity

Certification reports

PSU - EU Declaration of Conformity

Certification reports

RCM-AS, RCM-AR - EU Declaration of Conformity

Certification reports · en

SKU.1 CG-S - Declaration of Conformity

Certification reports · en

TLS.1 - EU Declaration of Conformity

Certification reports

3-PM Module - Mounting instructions

Installation instructions

3-PM-IO - Mounting instructions

Installation instructions

3-PM-IO-INV - Mounting instructions

Installation instructions

3PM-S Module - Mounting instructions

Installation instructions

Battery block monitoring - Mounting instructions

Installation instructions

Battery racks - Mounting and Operating Instructions

Installation instructions · en

DG-S - Short instructions

Installation instructions · en

DualGuard-S - Brief instruction Function Test and fault location

Installation instructions

DualGuard-S - Mounting instructions

Installation instructions · en

DualGuard-S ESF30 - Mounting and Operating Instructions

Installation instructions · en

DualGuard-S ESF30 Compact fan set - Mounting instructions

Installation instructions

DualGuard-S ESF30 KV - Mounting and Operating Instructions

Installation instructions · en

RCM-A - Mounting and Operating instructions

Installation instructions

SOU CG-S 2 x 4A - Mounting instructions

Installation instructions

3PM-S - End-of-Life Instructions

Manuals and user guides

3PM-S - Quick start guide

Manuals and user guides · en

8PM-I-Bus module - Quick start guide

Manuals and user guides · en

DualGuard-S ESF30 - Mounting and operations instructions

Manuals and user guides · en

Compatibility Matrix

Product specification guides

Eaton Location Plans IDLS

Product specification guides

Eaton Location Plans SCM

Product specification guides

Eaton Life Safety products - Reference book

Success stories · en

3PM-S Module - Datasheet

Technical data sheets · en

DualGuard-S - Datasheet

Technical data sheets · en

DualGuard-S 3-PM-IO & 3-PM-IO-INV module - Data sheet

Technical data sheets

DualGuard-S AC trafo - Data sheet

Technical data sheets

DualGuard-S ACU DG-S module - Data sheet

Technical data sheets

DualGuard-S BBS Battery Block Sensor - Data sheet

Technical data sheets · en

DualGuard-S BCM.1 module - Data sheet

Technical data sheets

DualGuard-S CG IV.1 relay module - Data sheet

Technical data sheets

DualGuard-S CG V.1 relay module - Data sheet

Technical data sheets

DualGuard-S CM.1 1.7 A & 3.4A charging module - Data sheet

Technical data sheets

DualGuard-S ESF30 Ventilation Set - Datasheet

Technical data sheets · en

DualGuard-S SKU.1 CG-S 1x6 A - Data sheet

Technical data sheets

DualGuard-S SKU.1 CG-S 2x3 A - Data sheet

Technical data sheets

DualGuard-S SKU.1 CG-S 4x1.5 A - Data sheet

Technical data sheets

DualGuard-S SOU CG-S 2x4 A - Data sheet

Technical data sheets

DualGuard-S TFT touch display - Data sheet

Technical data sheets

DualGuard-S TLS bus module - Data sheet

Technical data sheets

RCM-A - Data sheet

Technical data sheets · en

DualGuard-S - Tender text

Technical service bulletins · en

RCM-A - Tender text

Technical service bulletins