Eaton DualGuard-S - Central battery emergency lighting system
The DualGuard-S central battery system supplies safety and escape sign luminaires with reliable power (230 V AC/220 V DC), automatically checks itself and monitors each of the connected CG-S luminaires (up to 20 per circuit) directly via the supply cable. Thanks to the STAR technology, the switching
Request a quoteDescription
The DualGuard-S central battery system supplies safety and escape sign luminaires with reliable power (230 V AC/220 V DC), automatically checks itself and monitors each of the connected CG-S luminaires (up to 20 per circuit) directly via the supply cable. Thanks to the STAR technology, the switching mode of each connected CG-S luminaire in a 50 Hz or 60 Hz network can be programmed as required via the central battery system controller. This means that mixed operation of the continuous light, switched continuous light and standby light modes is possible in one and the same circuit - without any additional data cable. The central battery system can be monitored and controlled via the ACU DG module and the 4.3" or 7" display with non-volatile program memory. The system automatically checks the functioning of all connected devices and emergency luminaires and will issue an alert in the event of a fault.
Eaton emergency lighting systems, over 50 years of safe evacuation expertise
Our reliable and high quality products are known and specified worldwide. The passion and expertise of our employees ensures comprehensive, future-oriented solutions and high customer satisfaction.
Order details
- Order no. | Type | Included with delivery
- 40071362511 | DualGuard-S 28 | Free-standing cabinet with optimized wiring system for central battery system CEAG DualGuard-S 28, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 88 final circuits, or a maximum of 28 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
- 40071362510 | DualGuard-S 20 | Free-standing cabinet with optimized wiring system for central battery system CEAG DualGuard-S 20, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 88 final circuits, or a maximum of 20 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
- 40071362540 | DualGuard-S LAD 100 | Free-standing cabinet for central battery system CEAG DualGuard-S LAD 100A, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 16 final circuits, or a maximum of 4 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
- 40071362520 | DualGuard-S 12C | Compact cabinet for central battery system CEAG DualGuard-S 12C, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 48 final circuits, or a maximum of 12 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
- 40071362523 | DualGuard-S 12C6 | Compact cabinet for central battery system CEAG DualGuard-S 12C6, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 48 final circuits, or a maximum of 12 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
- 40071362524 | DualGuard-S 20C6 | Compact cabinet for central battery system CEAG DualGuard-S 20C6, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 68 final circuits, or a maximum of 20 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
- 40071362521 | DualGuard-S 12C4 | Compact cabinet for central battery system CEAG DualGuard-S 12C4, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 48 final circuits, or a maximum of 12 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
- 40071362525 | DualGuard-S 4C3 | Compact cabinet for central battery system CEAG DualGuard-S 4C3, equipped with battery control module (BCM.1), advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 20 final circuits, or a maximum of 5 variable circuit boards. Please note! The CM charging modules and the TFT touch display are not part of the cabinet module.
- 40071362513 | DualGuard-S US 38 | Free-standing cabinet for substations CEAG DualGuard-S US-S 38, equipped with advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 88 final circuits, or a maximum of 38 variable circuit boards. Please note! The TFT touch display is not part of the cabinet module.
- 40071362512 | DualGuard-S US 30 | Free-standing cabinet for substations CEAG DualGuard-S US-S 30, equipped with advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 88 final circuits, or a maximum of 30 variable circuit boards. Please note! The TFT touch display is not part of the cabinet module.
- 40071362532 | DualGuard-S US 23 | Wall cabinet for CEAG DualGuard-S US-S 23 substations, equipped with advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 52 final circuits, or a maximum of 23 variable circuit boards. Please note! The TFT touch display is not part of the cabinet module.
- 40071362531 | DualGuard-S US 15 | Wall cabinet for CEAG DualGuard-S US-S 15 substations, equipped with advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 32 final circuits, or a maximum of 15 variable circuit boards. Please note! The TFT touch display is not part of the cabinet module.
- 40071362530 | DualGuard-S US 7 | Wall cabinet for CEAG DualGuard-S/US-S 7 substations, equipped with advanced control unit (ACU DG-S) and power supply unit (PSU). For installing a 4.3" or 7" TFT touch display. With extra space for adding a maximum of 28 final circuits, or a maximum of 7 variable circuit boards. Please note! The TFT touch display is not part of the cabinet module.
- 40071362519 | DualGuard-S US SOU2 | Small distribution board for DualGuard-S/US-S SOU2 substations, equipped with two SOU CG-S 2x4A circuit modules
- 40071362518 | DualGuard-S US SOU1 | Small distribution board for DualGuard-S/US-S SOU1 substations, equipped with one SOU CG-S 2x4A circuit module
- 40071362516 | DualGuard-S ESF30 15-P | Wall cabinet for substations with 30 minutes of functional integrity during fire from outside CEAG DualGuard-S ESF30 15-P, equipped with 4.3" TFT touch display, advanced control unit (ACU DG-S) and power supply unit (PSU). With extra space for adding a maximum of 40 final circuits, or a maximum of 15 variable circuit boards.
- 40071362517 | DualGuard-S ESF30 30P | Free-standing cabinet for substations with 30 minutes of functional integrity during fire from outside CEAG DualGuard-S ESF30 30-P, equipped with 4.3" TFT touch display, advanced control unit (ACU DG-S) and power supply unit (PSU). With extra space for adding a maximum of 58 final circuits, or a maximum of 30 variable circuit boards.
- 40071362538 | DualGuard-S ESF30 SOU5 | Wall cabinet for substations with 30 minutes of functional integrity during fire from the outside DualGuard-S ESF30 SOU5, equipped with five SOU CG-S 2x4A circuit modules
- 40071362537 | DualGuard-S ESF30 SOU3 | Wall cabinet for substations with 30 minutes of functional integrity during fire from outside DualGuard-S ESF30 SOU3, equipped with three SOU CG-S 2x4A circuit modules
- 40071362536 | DualGuard-S ESF30 SOU2 | Wall cabinet for substations with 30 minutes of functional integrity during fire from the outside DualGuard-S ESF30 SOU2, equipped with two SOU CG-S 2x4A circuit modules
- 40071362535 | DualGuard-S ESF30 SOU1 | Wall cabinet for substations with 30 minutes of functional integrity during fire from the outside DualGuard-S ESF30 SOU1, equipped with one SOU CG-S 2x4A circuit module
Product family: specifications and ordering options vary by model. Refer to the model details and official documentation.
Documents & Technical Downloads
DualGuard-S - EULA Firmware EN
Application notes · en
DualGuard-S - Brochure
Brochures · en
Emergency Lighting (Central Battery Systems) - Global Catalogue
Catalogues · en
3-PM / 3-PM-IO / 3-PM-IO-INV - Attestation of Conformity
Certification reports
8PM-I-Bus module / 3PM-S - EU Declaration of Conformity
Certification reports
BBM - EU Declaration of Conformity
Certification reports · en
BCM.1 - EU Declaration of Conformity
Certification reports
CM 3.4A - EU Declaration of Conformity
Certification reports
DualGuard-S (CEAG) - UAE
Certification reports · en
DualGuard-S - Attestation of Conformity
Certification reports · en
DualGuard-S - Declaration of Conformity
Certification reports · en
DualGuard-S - ENEC
Certification reports · en
DualGuard-S - ESF30 EU Declaration of Conformity
Certification reports
DualGuard-S - KEMA-KEUR
Certification reports · en
DualGuard-S with BBM - EU Declaration of Conformity
Certification reports · en
HMI + ACU DG-S - EU Declaration of Conformity
Certification reports
PSU - EU Declaration of Conformity
Certification reports
RCM-AS, RCM-AR - EU Declaration of Conformity
Certification reports · en
SKU.1 CG-S - Declaration of Conformity
Certification reports · en
TLS.1 - EU Declaration of Conformity
Certification reports
3-PM Module - Mounting instructions
Installation instructions
3-PM-IO - Mounting instructions
Installation instructions
3-PM-IO-INV - Mounting instructions
Installation instructions
3PM-S Module - Mounting instructions
Installation instructions
Battery block monitoring - Mounting instructions
Installation instructions
Battery racks - Mounting and Operating Instructions
Installation instructions · en
DG-S - Short instructions
Installation instructions · en
DualGuard-S - Brief instruction Function Test and fault location
Installation instructions
DualGuard-S - Mounting instructions
Installation instructions · en
DualGuard-S ESF30 - Mounting and Operating Instructions
Installation instructions · en
DualGuard-S ESF30 Compact fan set - Mounting instructions
Installation instructions
DualGuard-S ESF30 KV - Mounting and Operating Instructions
Installation instructions · en
RCM-A - Mounting and Operating instructions
Installation instructions
SOU CG-S 2 x 4A - Mounting instructions
Installation instructions
3PM-S - End-of-Life Instructions
Manuals and user guides
3PM-S - Quick start guide
Manuals and user guides · en
8PM-I-Bus module - Quick start guide
Manuals and user guides · en
DualGuard-S ESF30 - Mounting and operations instructions
Manuals and user guides · en
Compatibility Matrix
Product specification guides
Eaton Location Plans IDLS
Product specification guides
Eaton Location Plans SCM
Product specification guides
Eaton Life Safety products - Reference book
Success stories · en
3PM-S Module - Datasheet
Technical data sheets · en
DualGuard-S - Datasheet
Technical data sheets · en
DualGuard-S 3-PM-IO & 3-PM-IO-INV module - Data sheet
Technical data sheets
DualGuard-S AC trafo - Data sheet
Technical data sheets
DualGuard-S ACU DG-S module - Data sheet
Technical data sheets
DualGuard-S BBS Battery Block Sensor - Data sheet
Technical data sheets · en
DualGuard-S BCM.1 module - Data sheet
Technical data sheets
DualGuard-S CG IV.1 relay module - Data sheet
Technical data sheets
DualGuard-S CG V.1 relay module - Data sheet
Technical data sheets
DualGuard-S CM.1 1.7 A & 3.4A charging module - Data sheet
Technical data sheets
DualGuard-S ESF30 Ventilation Set - Datasheet
Technical data sheets · en
DualGuard-S SKU.1 CG-S 1x6 A - Data sheet
Technical data sheets
DualGuard-S SKU.1 CG-S 2x3 A - Data sheet
Technical data sheets
DualGuard-S SKU.1 CG-S 4x1.5 A - Data sheet
Technical data sheets
DualGuard-S SOU CG-S 2x4 A - Data sheet
Technical data sheets
DualGuard-S TFT touch display - Data sheet
Technical data sheets
DualGuard-S TLS bus module - Data sheet
Technical data sheets
RCM-A - Data sheet
Technical data sheets · en
DualGuard-S - Tender text
Technical service bulletins · en
RCM-A - Tender text
Technical service bulletins