Eaton Adaptive Evacuation - Building evacuation system control unit
Emergency Lighting Control & Monitoring

Eaton Adaptive Evacuation - Building evacuation system control unit

Eaton·SKU: EATON-F-BB2F38A7A5A2

Adaptive Evacuation Control Unit for wall mounting with integrated battery-supported power supply or for assembly in ZB-S/18-AE units using loop technique for controlling addressable adaptive exit sign luminaires with 230V / 216V AC/DC technology for safety lighting systems acc. to DIN VDE 0100-560,

Request a quote

Description

Adaptive Evacuation Control Unit for wall mounting with integrated battery-supported power supply or for assembly in ZB-S/18-AE units using loop technique for controlling addressable adaptive exit sign luminaires with 230V / 216V AC/DC technology for safety lighting systems acc. to DIN VDE 0100-560, DIN EN 50172 and V DIN V VDE 0108-100. With automatic testing device and monitoring of loop bus communication and individual display of condition and name of loop BUS connection per GuideLed DXC luminaire.

Highlights

  • AE-CU technology: Active response to ever-changing dangerous situations
  • Decentral configuration: Control up to 240 GuideLed DXC exit signs
  • Self-addressing: Simplified installation and commissioning of GuideLed DX/DXC exit sign

Safer evacuation with no additional cabling

Due to separate cable routing of the 230V end circuits and 24V loop bus line to the adaptive GuideLed DXC exit sign luminaires, the hybrid operation of static and adaptive exit sign luminaires and the integration of escape luminaires and luminaires for general lighting is possible in the same circuit.

Short circuit and open circuit resistant loop bus technology

The Adaptive Evacuation control panel features short circuit and open circuit resistant loop bus technology. This means no E30 cable routing of the loop bus line is required because these are fail-safe with the first fault case.

Wall Mounted AE-CU-W Ordering details

  • Order code | Description
  • 40071361359 | AE-CU-W, Surface- / Recessed mounted wall housing

Installation Variant (AE-CU-E) Ordering details

  • Order code | Description
  • 40071361360 | *AE-CU-E, Installation variant for ZB-S/18-AE
  • *note: not suitable for AT-S+ and LP-STAR systems

Installation Variant (AE-CU-E) Technical Specifications

  • Primary rated voltage | 28.5 V/DC
  • Primary rated current | 4.2 A
  • Protection rating | IP 20
  • Insulation class | I
  • Ambient temperature | -5°C to+40°C
  • Secondary rated voltage | 18.5 V - 29.6 V
  • Weight | 8 kg
  • Dimensions (HxWxD in mm) | 200 x 500 x 190
  • Material | Sheet steel, powder-coated
  • Inputs |
  • Addressable loop line | 4
  • Scenario active inputs | 2 (more on request)
  • Maximum ring length | 2,000 m / I(ST)Y 4 x 2 x 0.8 mm
  • Maximum number of GuideLed DX/DXC luminaires per loop | 60
  • Outputs |
  • Zero-potential changeover contact | 2
  • Contact load | 24 V / 1 A
  • Fuse | 1.35 A

Product family: specifications and ordering options vary by model. Refer to the model details and official documentation.

Official Eaton product page

Technical Specifications

Addressable loop line4
Ambient temperature-5°C to+40°C
Basic housing materialSheet steel, powder-coated
Battery2 x 12 V / 12 Ah
Charge characteristicConstant voltage temperature-compensated
Contact load24 V / 1 A
Dimensions (HxWxD in mm)395 x 495 x 180
Fuse1.35 A
Insulation classI
Manufacturer highlight: AE-CU technologyActive response to ever-changing dangerous situations
Manufacturer highlight: Decentral configurationControl up to 240 GuideLed DXC exit signs
Manufacturer highlight: Self-addressingSimplified installation and commissioning of GuideLed DX/DXC exit sign
Material of frontPlastic
Max. battery current3.5 A
Maximum number of GuideLed DX/DXC luminaires per loop60
Maximum ring length2,000 m / I(ST)Y 4 x 2 x 0.8 mm
Min. backup power time30 h
Nominal frequency50 Hz
Primary rated current75 mA
Primary rated voltage230 V AC +10%, -15%
Protection ratingIP 30
Scenario active inputs2 (more on request)
Secondary rated voltage18,5 V - 29,5 V
Weight with battery14 kg
Zero-potential changeover contact2

Documents & Technical Downloads