Communication Gateways
DS Dialer
Notifier·SKU: P2407002
The Honeywell® solution for connecting a NOTIFIER Onyx, INSPIRE, or Gamewell-FCIE3,S3 fire alarm system to central station viathe public switched telephone network.
Request a quoteDescription
The DS Dialer provides dual telephone line communication between a standalone FACP
or network of FACPs to a central receiving station to report system status. The DS Dialer
mounts in a red enclosure external to a fire panel It uses modular jacks to interface the
primary and secondary phone lines to the public switched telephone network.
The DS Dialer consists of a main circuit board and telephone (POTS) card enclosed
in a red box.
Features & Benefits:- COMPATIBLE PANELS
- NOTIFIER INSPIRE PANELS: N16E, N16X
- NOTIFIER ONYX PANELS: NFS-320, NFS-640, NFS2-640, NFS-3030, NFS2-3030
- GAMEWELL-FCI E3 SERIES PANEL: ILI-MB-E3, ILI95-MB-E3
- GAMEWELL-FCI S3 SERIES PANELS: SLP-E3
- COMPATIBLE RECEIVERS
- Ademco™ 685 (with 685-8 Line card with Rev. 4.4d software)
- Ademco MX8000 (with 124060V206B and 124063 Line Card Rev. B)
- Silent Knight® 9500 (with version V2.4 receiver and 126047 Line Card Rev. G)
- Silent Knight 9800 (with 124077V2.00 receiver and 126047 Line Card Rev. M)
- Honeywell® FBI CP220FB (with software version 3.9)
- Osborne Hoffman 2000E® (with receiver software version 7301)
- Radionics 6600 (with 01.01.03 receiver software and 01.01.03 line card)
- SurGard MLR2 (with software version 1.86)
- SurGard System III (with software 1.72)
- SurGard MLR-2000 (with DSP4016 and version 1.6 Line Card)
- COMMUNICATION FORMATS
- Ademco Contact ID
- FEATURES AND BENEFITS
- Collects system data from the connected FACP and sends it to the central receiving station
- Serves as a fire alarm communicator to the central station
- Provides dual telephone lines (primary and backup) to ensure communication
- Provides dual telephone line voltage detection
- Employs Ademco® Contact ID protocols
- Recognizes dial tones (350 and 440 hertz typical in most networks)
- Automatically dials programmed central station phone numbers
- Automatic line seizure takes control and disconnects any local premises phones on the same line
- Generate Central Station reports using CLSS Site Manager
- LED status indicators for Lost Panel Connection, and Central Station Handshake Signal, and Communication
- Failure
- Communicates vital system status including:- Independent zone/point alarm, trouble and supervisory- Security, panel off-normal, NAC trouble- AC (main) power loss (2-hour report delay)
- AGENCY LISTINGS & APPROVALS
- The listings and approvals below apply to the HON-DACT-DS.
- In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Contact Honeywell for the latest listings.
- ETL: Control Number - 5025335, Conforms to UL STD 864
- STANDARDS & CODES
- FCC ID: DS Dialer - 1W6AL02ACGWMB
- National Fire Protection Association:- NFPA 70- NFPA 72
Technical Specifications
| Brand | NOTIFIER |
|---|---|
| Communicates vital system status including | - Independent zone/point alarm, trouble and supervisory- Security, panel off-normal, NAC trouble- AC (main) power loss (2-hour report delay) |
| ETL | Control Number - 5025335, Conforms to UL STD 864 STANDARDS & CODES FCC ID: DS Dialer - 1W6AL02ACGWMB National Fire Protection Association:- NFPA 70- NFPA 72 |
| Failure Communicates vital system status including | - Independent zone/point alarm, trouble and supervisory- Security, panel off-normal, NAC trouble- AC (main) power loss (2-hour report delay) |
| FCC ID | DS Dialer - 1W6AL02ACGWMB National Fire Protection Association:- NFPA 70- NFPA 72 |
| National Fire Protection Association | - NFPA 70- NFPA 72 |