Apollo 58100-976MAR Discovery Marine Manual Call Point – Outdoor – Isolating [SIL2]
Addressable Manual Call Points

Apollo 58100-976MAR Discovery Marine Manual Call Point – Outdoor – Isolating [SIL2]

Apollo·SKU: 58100-976MAR

The Manual Call Point is used to manually initiate an alarm signal on the fire detection system.

Request a quote

Description

The Manual Call Point is used to manually initiate an alarm signal on the fire detection system.

  • Suitable for weatherproof applications
  • EN 54-11 & EN 54-17 Certified
  • Reports an alarm in under 0.2 seconds
  • ‘Plug and Play’ terminal connections for faster wiring
  • Continuity link for wiring test before commissioning
  • XP95 & Discovery compatible

Official Apollo product information

Technical Specifications

Conformance - ApprovalsCCS, DNV.GL, ESC, MED
Electrical - Maximum power-up time1 second
Electrical - PolarityL1 &, L2 are polarity sensitive
Electrical - Power-up surge current1mA
Electrical - Protocol voltage5 to 9V peak to peak
Electrical - Protocol voltage (max)9V
Electrical - Protocol voltage (min)5V
Electrical - Quiescent current100μA
Electrical - Quiescent current tested at24V dc
Electrical - Terminal functions L1 in-L1 in, Loop (isolated) negative
Electrical - Terminal functions L2-L2, Line in & out negative
Environmental - Humidity0% to 95% (no condensation or icing)
Environmental - Humidity (max)95%, RH
Environmental - Humidity (min)0%, RH
Environmental - Humidity Noteno condensation or icing
Environmental - IP rating ValueIP67
Environmental - Operating temperature-20 to 60°C / -4 to 140°F
Environmental - Operating temperature (max)60°C / 140°F
Environmental - Operating temperature (min)-20°C / -4°F
General - Warranty3 year
Mechanical - ColourWhite
Mechanical - Detection principleOperation of a switch.
Mechanical - Key typeKAC, Manal, Call, Point test & reset key
Mechanical - Materials housingPolycarbonateABS
Mechanical - Product depth93mm / 3.66in
Mechanical - Product length27mm / 1.06in
Mechanical - Product width89mm / 3.5in
Performance - Alarm level analogue value64
Performance - Analogue value nominal16

Documents & Technical Downloads

Simplex 4090-9005 (IDNET Release Peripheral)

Simplex 4090-9005 (IDNET Release Peripheral)

Indicative Price

from

Addressable Manual Call Point – Glass Element

Addressable Manual Call Point – Glass Element

Indicative Price

from

Addressable Manual Call Point with Built-in Isolator – Glass Element

Addressable Manual Call Point with Built-in Isolator – Glass Element

Indicative Price

from

Addressable Manual Call Point with Built-in Isolator – Glass Element

Addressable Manual Call Point with Built-in Isolator – Glass Element

Indicative Price

from