Apollo 55000-650APO XP95A Photoelectric Smoke Detector (Obsolete)
Smoke Detectors

Apollo 55000-650APO XP95A Photoelectric Smoke Detector (Obsolete)

Apollo·SKU: 55000-650APO

The XP95A Photoelectric Smoke Detector uses the light scatter principle to quickly and effectively detect a range of slow burning and smouldering fires.

Request a quote

Description

This product is now obsolete and is replaced with the XP95A Multi-Criteria Detector (Smoke/Heat) – UL268 7th Edition.

The XP95A Photoelectric Smoke Detector uses the light scatter principle to quickly and effectively detect a range of slow burning and smouldering fires.

  • Reliable fire detection in areas with a wide temperature range from 32°F to 100°F
  • Ideal for escape routes
  • Unaffected by wind and atmospheric pressure
  • Insect resistant screen

Official Apollo product information

Technical Specifications

Conformance - ApprovalsFM, SII, UL
Conformance - StandardsEN 54-7
Electrical - Battery poweredNo
Electrical - Maximum power-up time4 seconds
Electrical - PolarityL1 &, L2 are polarity insensitive
Electrical - Power-up surge current1mA
Electrical - Protocol voltage5 to 9V peak to peak
Electrical - Protocol voltage (max)9V
Electrical - Protocol voltage (min)5V
Electrical - Quiescent current340μA
Electrical - Quiescent current tested at24V dc
Electrical - Sampling frequencyOnce per second
Electrical - Status indicator – AlarmRed
Electrical - Supply voltage (max)28V dc
Electrical - Supply voltage (min)17V dc
Electrical - Supply voltage (Vmin-Vmax)17 to 28V dc
Electrical - Terminal functions -R-R, Remote indicator negative connection
Electrical - Terminal functions +R+R, Remote indicator positive connection
Environmental - Effect of wind speedNone
Environmental - Humidity0% to 95% (no condensation or icing)
Environmental - Humidity (max)95%, RH
Environmental - Humidity (min)0%, RH
Environmental - Humidity Noteno condensation or icing
Environmental - IP rating ValueIP23D
Environmental - Operating temperature-20 to 60°C / -4 to 140°F
Environmental - Operating temperature (max)60°C / 140°F
Environmental - Operating temperature (min)-20°C / -4°F
Environmental - Storage temperature-30 to 80°C
Environmental - Storage temperature (max)80°C
Environmental - Storage temperature (min)-30°C
General - ApplicationsBedrooms, Escape routes, Hotels, Medium to large buildings, Offices, Retail
General - Fire TypeSlow burning, smouldering fires
General - Warranty10 year
Manufacturer statusObsolete
Mechanical - ColourWhite
Mechanical - Detection principlePhoto-electric light scattering.
Mechanical - Materials housingPolycarbonate
Mechanical - Product depth42mm / 1.65in
Mechanical - Product diameter100mm / 3.94in
Mechanical - Sensor configurationHorizontal optical bench housing infra-red emitter and sensor, arranged radially to detect forward scattered light.
Mechanical - Weight105g
Performance - Alarm level analogue value55
Performance - Analogue value25 +7/-7
Performance - Analogue value (- tolerance)7
Performance - Analogue value (+ tolerance)7
Performance - Analogue value nominal25
Performance - Chamber typeChevron

Documents & Technical Downloads

Context Plus Smoke detector built in sounder

Context Plus Smoke detector built in sounder

Indicative Price

from

Simplex 4098-9714 Photoelectric Smoke Detector

Simplex 4098-9714 Photoelectric Smoke Detector

Indicative Price

from

Gentex S1209 Photoelectric Smoke Alarm, 120 VAC with 9V Battery Backup, 917-0059-002

Gentex S1209 Photoelectric Smoke Alarm, 120 VAC with 9V Battery Backup, 917-0059-002

Indicative Price

from