301C Controller
Flame Detectors

301C Controller

Notifier·SKU: 301CController

Monitor and control gas hazards efficiently with the 301C Controller, featuring advanced zoning, support for multiple transmitters, low maintenance, and reliable alarm management.

Request a quote

Description

Designed for simple installation and operation, the 301C continuously monitors and controls toxic gases, combustible gases and oxygen hazards.

Product Overview:

Using an addressable RS-485 Modbus communication protocol, the 301C uses daisy chain wiring requiring only 2 pairs of wires to connect up to 96 transmitters on the 3 input channels. This simplifies installation, in turn lowering costs. The 301C’s zoning and averaging abilities significantly reduce operational and maintenance costs.

Zoning / Averaging:

The 301C controller offers unique zoning capabilities which permit the averaging and comparison of multiple sensor readings. Zoning can reduce operational costs by ensuring that localized brief fluctuations registered at a single transmitter do not activate relays. For example, a car idling in a parking structure may locally increase a reading at a nearby transmitter. Rather than activating a fan as a result of the temporary localized fluctuation, zoning can be used to limit relay activation until the average reading for a zone exceeds a set-point. This can reduce run time of fans, yielding savings in both energy usage and wear and tear. The 301C has the capacity to manage input from three Modbus channels for up to 96 transmitters and up to 50 wireless transmitters that can be associated with up to 126 zones. Transmitters can belong to an unlimited number of zones, providing maximum operational and control flexibility.

Additional Features and Benefits:

  • Zero maintenance
  • User Friendly
  • Automatic quick self-test and warm-up
  • Continuous alphanumeric display

Inexpensive and Reliable:

  • Low installation costs
  • Allows for up to 126 zoning groups which can save energy and extend fan and relay life
  • Manages up to 768 events with programmable latching alarms

Flexible Operation:

  • Optional BACnet/IP available
  • Interchangeable transmitters able to detect different gases
  • Expands to handle up to 96 transmitters or relay modules
  • Programmable time delays
  • Integrated time clock enables scheduling of system operations

Safety Measures:

  • Full array of visual indicators and integrated 65dBA alarm levels
  • Fully programmable relays (can be set as fail-safe or not)

Beneficial Options:

  • Available in a heavy-duty industrial housing
  • Datalogging option

Features & Benefits:

  • User friendly with zero maintenance
  • Low installation costs
  • Automatic quick self-test and warm-up

Quick Specs:

  • Power requirement: 17-27 VAC, 24-38 VDC, 500 mA
  • Size: 11 (W) x 8 (H) x 2.8 (D) in. (28 x 20.3 x 7 cm)
  • Weight: 2.4 lbs. (1.1 kg)

Official manufacturer product information

Additional manufacturer specifications

  • Features & Benefits: Allows for up to 126 Zoning Groups which can Save Energy and Extend Fan and Relay Life; Automatic Quick Self-Test and Warm-up; Available in a Heavy Duty Industrial Housing (Model No. 96D); BACnet/IP Available; California Title 24 Network Option; Continuous Alphanumeric Display; Expands to Handle up to 96 Transmitters or Relay Modules; Full Array of Visual Indicators and Integrated 65dBA Alarm Levels; Interchangeable Transmitters able to Detect Different Gases; Manages up to 180 Events with Programmable Latching Alarms; Programmable Time Delays and Integrated Time Clock Enables Scheduling of System Operations; Zero Maintenance and Low Installation Costs

Technical Specifications

Alarm IncludedYes
Alarm SettingsFully Programmable Alarm Levels
BrandHoneywell; Honeywell; Notifier
Communication Line LengthsT-Tap: 65 ft. (20 m), Maximum per T-Tap: 130 ft. (40 m), Maximum for All T-Tap Combined; Up to 2,000 ft. (609 m) per Channel
DataloggingDatalogging Option
Datalogging CapableYes
Decibels65
Digital Communication PortsOptional BACnet/IP Interface (BTL Listed as a Smart Sensor)
Display IncludedYes
Display Matrix122 x 32 Dot Matrix
Display ReadoutReal-Time Gas Reading
Display TypeLCD
GraphicDot Matrix Backlit Display
Humidity Range0 to 95% RH (Non-Condensing)
IndustryEnergy
Inlet FanYes
Maximum Temperature50
Minimum Temperature-20
NEMA RatingNEMA 4x
Number of Relay Outputs3
Operating Current500
Operating Frequency Range50/60 Hz
Optional Memory2 GB Removable SD Card for Configuration, Readings and Events
Power requirement17-27 VAC, 24-38 VDC, 500 mA
Relay IncludedYes
Relay Output Configuration4 DPDT Relays (Alarms and/or Fault); 65 dBA Buzzer
Relay Rated Load5A, 30V DC or 250V AC (Resistive Load)
Relay Wire Size2 to 24 AWG
SecurityPassword Protection for Tamper Resistance
Series Name301C
ShieldedYes
Size11 (W) x 8 (H) x 2.8 (D) in. (28 x 20.3 x 7 cm)
StandardsFor Canada: CAN/CSA C22.2 No. 61010-1:04 (2nd Edition); For USA: ANSI/UL 61010-1 (2nd Edition)
Sub-CategoryGas Detection Controllers; Plastic Enclosure
Time Delay0 sec; 1 to 99 min Before and After Alarm; 30 sec; 45 sec
Visual IndicatorsAlarm A: Red; Alarm B: Red; Alarm C: Red; Fault: Amber; Power On: Green; Rx: Green (Blinks when in Use); Tx: Amber (Blinks when in Use)
Weight2.4 lbs. (1.1 kg)
Weight range453.5
ZoningUp to 126 Programmable